Model | V-max (Vdc) | I-max (A) | I-hold (A) | I-trip (A) | Agency Approval |
R60-010 | 60 | 40 | 0.10 | 0.20 | UL/TUV/RoHS |
R60-017 | 60 | 40 | 0.17 | 0.34 | UL/TUV/RoHS |
R60-020 | 60 | 40 | 0.20 | 0.40 | UL/TUV/RoHS |
R60-025 | 60 | 40 | 0.25 | 0.50 | UL/TUV/RoHS |
R60-030 | 60 | 40 | 0.30 | 0.60 | UL/TUV/RoHS |
R60-040 | 60 | 40 | 0.40 | 0.80 | UL/TUV/RoHS |
R60-050 | 60 | 40 | 0.50 | 1.00 | UL/TUV/RoHS |
R60-065 | 60 | 40 | 0.65 | 1.30 | UL/TUV/RoHS |
R60-075 | 60 | 40 | 0.75 | 1.50 | UL/TUV/RoHS |
R60-090 | 60 | 40 | 0.90 | 1.80 | UL/TUV/RoHS |
R60-110 | 60 | 40 | 1.10 | 2.20 | UL/TUV/RoHS |
R60-135 | 60 | 40 | 1.35 | 2.70 | UL/TUV/RoHS |
R60-160 | 60 | 40 | 1.60 | 3.20 | UL/TUV/RoHS |
R60-185 | 60 | 40 | 1.85 | 3.70 | UL/TUV/RoHS |
R60-250 | 60 | 40 | 2.50 | 5.00 | UL/TUV/RoHS |
Ihold = Hold Current:maximum current device will sustain for 4 hours without tripping in 25℃ still air.
ItRip = Trip Current:minimum current at which the device will trip in 25℃ still air.
V-max = Maximum voltage device can withstand without damage at rated current(I-max).
I-max = Maximum fault current device can withstand without damage at rated voltage(V-max).